NZS 2295:2006 (A1 excl.) Pliable, permeable building underlays - Sponsored

Abbreviation
NZS 2295:2006 (A1 excl.)
Valid from
27/09/2006

Information provider
Standards New Zealand
Author
Standards New Zealand
Information type
New Zealand Standard
Format
PDF, HARD COPY


Description

Specifies the material property requirements and test methods for pliable and permeable building underlay material to be used for roofs and walls. This Standard does not include rigid materials used in place of pliable wall or roof underlay, pliable membranes used as insulation, vapour barriers or foil laminates.

Scope

The scope of this Standard is as follows. The scope of this Standard includes wall underlays fitted:

  • (a) Behind wall claddings directly fixed to timber, steel framing or thermal breaks of the steel framing; and
  • (b) Behind battens that form a drained and ventilated cavity behind wall claddings fixed to timber or behind the thermal break of steel framing.

The scope of this Standard includes roof underlays under roof claddings. The scope of this Standard does not include:

  • (a) Rigid materials used in place of pliable wall or roof underlay;
  • (b) Pliable membranes used as insulation;
  • (c) Vapour barriers used under concrete slabs or suspended timber floors;
  • (d) Vapour barriers behind wall or roof claddings; or
  • (e) Foil laminates.

This Standard does not cover installation; however, some guidance on recommended industry practice is provided in Appendix A to assist users to meet the requirements of this Standard.

For assistance with locating previous versions, please contact the information provider.
Notes/comments

The Building System Performance branch of MBIE has sponsored access to view and print a downloadable PDF copy of the un-amended cited version of this standard at no charge.

View on Information Provider website
For assistance with locating previous versions, please contact the information provider.

The Building System Performance branch of MBIE has sponsored access to view and print a downloadable PDF copy of the un-amended cited version of this standard at no charge.

This resource is cited by:

NZS 2295:2006 (A1 excl.) Pliable, permeable building underlays - Sponsored

This document is CITED BY:

NZS 2295:2006 (A1 excl.) Pliable, permeable building underlays - Sponsored

Description

Specifies the material property requirements and test methods for pliable and permeable building underlay material to be used for roofs and walls. This Standard does not include rigid materials used in place of pliable wall or roof underlay, pliable membranes used as insulation, vapour barriers or foil laminates.

View on Information Provider website
NZS 2295:2006 (A1 excl.) Pliable, permeable building underlays - Sponsored
Description

Specifies the material property requirements and test methods for pliable and permeable building underlay material to be used for roofs and walls. This Standard does not include rigid materials used in place of pliable wall or roof underlay, pliable membranes used as insulation, vapour barriers or foil laminates.

View on Information Provider website
This resource cites:

NZS 2295:2006 (A1 excl.) Pliable, permeable building underlays - Sponsored

This document CITES:
New Zealand Standards
Australian Standards
Other
Feedback